APPLICATIONS
        Suitable for most gas-
        phase filtration                                                 •  Gas Phase filtration

        applications including:                                          •  Rechargeable
       •  Catering
                                                                         •  Suitable for front or side access
       •  Museums                                                        •  Wide range of sizes & types
       •  Archives
       •  Airport buildings                                              •  Suits numerous applications
       •  Ozone reduction                                                •  High adsorption
       •  VOC removal                                                    •  Made in Britain
       •  Mortuary
       •  Medical
       •  Pharmaceuticals
       •  Micro-electronics
       •  Sewerage Plants
       •  General odour removal
                                                                    Rated Airflow           Rated Airflow
                                         Typical Panel Size   Active carbon     Resistance at 0.1     Resistance at
                                                                   (m3/hr) at 0.1sec         (m3/hr) at
                                            (HxWxD        Weight                  sec (pa)             0.2 sec (pa)
                                                                      dwell                 0.2 sec dwell
       CONSTRUCTION
       The standard loose-fill           592x592x23mm     3.7kg        290          200        145       85
       panels are manufactured
       throughout in galvanised
       mild steel and provided                          Maximum Operating Temperature 40 c   Maximum Humidity 80%RH
                                                                              o
       with rigid internal braces.
       The durable cell will easily
       accept the forces necessary

       to ensure a suitable carbon                Application       Recommended          Grade          Ref
                                                                     Dwell Time *
       fill without bellying or
       distortion. The panel is           Cooking - Spicy, Indian    0.2 < 0.4 Seconds    General Purpose Activated Carbon    -7C
       provided with a removable
                                          Reduction of Kerosene Exhaust fumes    0.1 < 0.2 Seconds    General Purpose Activated Carbon    -7C
       end channel located by
       machine screws into                Reduction of Ozone        0.1 < 0.2 Seconds    General Purpose Activated Carbon    -7C
       threaded bushes that are           Reduction of Diesel Fumes     0.2 Seconds    5% Copper Treated Carbon    -9M
       simply removed for filter
                                          Reduction of H 2S, SO 2, NO 2, HCl   0.2 Seconds    5% Copper Treated Carbon    -9M
       replenishment using a
       standard cross-head                Museum and Archives protection   0.2 Seconds    5% Copper Treated Carbon    -9M
       screwdriver.                       Mortuary / formaldehyde reduction    0.4 Seconds    Mortuary Grade    -MO

                                          Ammonia Neutralisation     0.3 seconds      Ammonia Grade     -AM

                                                      Note *  Dwell time is the contact time that the air is within the carbon matrix